products   |   news   |   about us   |   contact us » home  ·  email  ·   ESPAÑOL
   solutions  ·  devices  ·  software  ·  training
Ingenium's wide range of design devices can cater for all kinds of installations:

From detached homes, blocks of flats or offices and hotels or shops and deparment stores.

go back devices INDEX
All Ingenium products carry a two-year guarantee from defects due to materials or manufacturing.

Quality is an important part of Ingenium's company philosophy.
graphic controls
ETHBUS2
WEB server to control BUSing® installations
Enables the installation to be controlled via Internet using a conventional Web navigator.






•  ETHERNET-BUSing® interface.
Web server incorporated.
Totally graphic interface.
Two BUSing® interfaces.
256 Kbytes to store installation plans and information.
Controls and monitors the entire installation via Internet.
Adjustable IP using the Development System (SIDE).
Executes scenes and controls timed events.
Chronothermostat.
Size: DIN rail, 6 modules.


Description

Allows installation controlling from any device connected to the Internet with a conventional WEB browser. Includes 2 BUSing®accesses, one ETHERNET 10Mbit/s port.

The device asks for a password to access the installation contolling and then shows its status according to what have been programmed through Development System (SIDE). This is a totally graphic and intuitive interface, and allows to control the installation in an easy way.

Allows to execute scenes and timed events. It also includes chronothermostat to do a hourly control of the heating.

With this device, the installation can be programmed remotely. A port will need to be opened in the installation router.


Technical Characteristics
Inputs

• HTTP requests via ETHERNET connection (protocol TCP, port 80).

Outputs

• 2 BUSing® ports.
• One of the ports can be used to connect IP cameras.


Supply
Voltage

230V AC
Power
Consumption

2.8VA


Download Installation Manual

ETHBUS2_installation.pdf

go back